Low-rise healthcare facilities
Multidisciplinary health centre over four storeys
This design arranges several health functions within a vertical building: imaging and diagnostics on the ground floor, laboratories on the first floor, consultations and administrative functions on the second, then management in part of the top level.
Stacking reduces the ground footprint compared with an entirely single-storey arrangement. It does, however, introduce additional constraints: accumulated loads, lateral stability, movement of patients and equipment, continuity of the services, compartmentation, accessibility, means of escape and maintenance.
The plans constitute a basis for organisation. They define neither a complete medical brief nor a structural solution ready to be manufactured. Each level must be adjusted according to the activities actually planned, the equipment chosen and the requirements applicable to the project.

Key details of this design
- Family
- Low-rise healthcare facilities
- Storeys
- Four storeys
- Published documents
- concept drawings
These details describe the design as presented. Floor areas, capacity and performance are not given: they are defined during the study of your project.
What this design shows
The first three levels repeat a comparable longitudinal geometry, structured around a main circulation route and a central core. This regularity may allow certain facade grids, certain panels, portions of floor and several vertical passages to be repeated.
The uses nevertheless remain very different from one storey to the next.
The ground floor includes a set of imaging and diagnostic rooms, together with control, reception, consultation, laboratory and support spaces. Several of the machines shown would require specific coordination with the slab, the foundations, the shielding, the electrical supply, the cooling and the delivery routes.
The first floor is mainly given over to laboratories. The succession of rooms may favour a repetitive grid, but the needs of each laboratory cannot be inferred from its name alone. Biological or chemical risks, equipment, fluids, ventilation, air pressures and waste handling must be defined by the technical brief.
The second floor groups medical and dental consultations, administrative spaces, meeting and training rooms and support rooms. The loads there may be less concentrated than in certain imaging or laboratory zones, without being uniform for all that.
On the third floor, management occupies a central core. The two large lateral zones have no defined brief on the plans: their use and fit-out conditions remain to be established during the study, without treating them from the outset as plant rooms, available floor area or extensions ready for use.
Repeating a grid without standardising the uses
The length and the regularity of the two main facades make it possible to consider repeating bays. That repetition may concern the studs, the facade panels, the windows, certain joists and several connection details.
It does not mean that all the panels are identical. The doors, the risers, the fixed equipment, the radiation shielding, the openings and the bracing requirements produce specific components.
Repetition must be sought within a controlled structural grid. The genuinely recurring zones are prepared as such; the singular ones are studied separately rather than forced into a module that would not match their function.
Where a programme comprises several comparable centres, a common base can be developed for certain panels, consultation rooms, layouts or facade details. Each building nevertheless remains recalculated according to its site, its equipment, its dimensions and the applicable climatic or seismic actions.
Bringing the loads down through four storeys
In a multi-storey building, the loads of the upper levels accumulate progressively down to the foundations. The load-bearing walls, beams, lintels and supports must be organised so as to form continuous load paths.
Aligning the main load-bearing lines vertically generally limits complex transfers. Where a level calls for a wider room, a different corridor or an opening that interrupts that alignment, a transfer component may become necessary. That decision affects the floor depth, the connections and the technical passages.
The long circulation routes and the number of doors reduce the portions of wall available for bracing. Horizontal stability must be distributed between solid panels, cross walls, the floor and roof diaphragms, their connections and the anchors.
The partly occupied top level introduces a change of geometry. Any setbacks, roof areas, upstands and changes of facade must be coordinated with the transfer of the forces and the continuity of the envelope.
Floors, vibration and equipment
A floor intended for a health centre is not defined by its distributed load alone. Some machines apply concentrated loads, produce vibration or call for great stability of their support.
A lightweight solution on joists may suit certain zones where the spans, the loads, the deflection, the vibration, the acoustics and fire allow it. A reinforced dry build-up or a steel-concrete composite slab may be studied where more mass, stiffness or continuity is needed.
The choice may vary from one level or one zone to another. It would not be coherent to size a meeting room, an equipped laboratory and a room intended for heavy medical equipment in the same way.
Placing the imaging equipment on the ground floor may limit its interaction with the upper floors. It does not remove the study of the slab, the foundations, the vibration, the anchors or the route allowing these machines to be brought in and replaced.
Medical imaging: preparing the room with the equipment
An imaging room is designed from the characteristics of the machine actually chosen. Its dimensions, its mass, its clearances, its supply, its cooling, its associated rooms and its installation route must be known early enough.
Equipment producing X-rays calls for a radiation protection study. The walls, doors, glazing, floors and ceilings concerned must receive the shielding determined by the competent specialist. A later change to the machine, to its orientation, to its workload or to the use of the neighbouring rooms may require a reassessment.
An MRI room raises different questions. It must not be treated as a simple radiology room. Control of the magnetic field, protection against radiofrequency interference, controlled access, technical penetrations and any emergency provisions are developed from the requirements of the equipment.
The presence of a steel structure does not, by itself, allow the conclusion that an MRI room is compatible or incompatible. The position and the nature of the steel components, the shielding, the services and the other equipment must be coordinated with the MRI specialist and with the data of the chosen manufacturer.
The openings, reinforcement and interfaces are built in before manufacture. An opening made afterwards in a wall or a floor may simultaneously affect the structure, the shielding, the air tightness and the fire protection.
Laboratories: the name of a room is not enough
The plans distinguish several families of laboratory. Their presence on the same floor may make it easier to share certain services and support spaces, but their needs are not automatically identical.
The level of containment, the movement of samples, the separation between clean and exposed zones, staff access, safety equipment and waste management must be determined from the real activities.
Ventilation may call for specific flow rates, filtration, extraction or pressure relationships. The ducts required occupy part of the ceilings and pass through the floors. Their route must be reserved without cutting the joists, the bracing or the connections.
The benches and machines may call for water, drainage, electricity, data, gases, cooling or local extraction. These supplies must reach risers that are accessible and maintainable.
Moving a laboratory later does not therefore mean moving a partition. It may change the services, the loads, the ventilation, the treatment of effluent, the fire protection and the conditions under which samples and waste circulate.
Stacking the services
A vertical building makes it possible to group certain risers between the levels. This arrangement becomes efficient where the wet rooms, the sanitary facilities, the technical equipment and the distribution points are coordinated within a single grid.
Drainage calls for falls and penetrations that cannot always be moved freely. The main pipes, ventilation ducts, cable trays and data networks must cross the floors in prepared zones.
Concentrating laboratories on one level and imaging equipment on the ground floor may lead to significant needs in electricity, air conditioning, data and continuity of service. The plant rooms and the capacity of the services are sized from the equipment chosen, not from the floor area of the building alone.
The schematic plans do not show all this infrastructure. They therefore do not allow the conclusion that the risers, plant rooms or capacities required are already provided for.
Horizontal and vertical circulation
The longitudinal layout makes the levels easy to read, but it produces significant distances between certain functions. The routes of patients, staff, visitors, samples, consumables, cleaning and waste must be studied separately.
The stairs and the lift shown give an intention for vertical circulation. They do not demonstrate that their number, their dimensions, their capacity or their position answer the final brief.
The choice of lift depends on the people and the equipment to be carried. A car intended mainly for visitors does not have the same dimensions or the same loads as one that must take a stretcher, technical equipment or certain medical devices.
The exits, escape routes, compartments and waiting areas must be verified according to the occupancy, the uses, the mobility of the occupants and the applicable rules. Adding rooms or occupying a zone that carries no brief today may change that strategy.
Envelope, acoustics and fire protection
Repeating the windows may simplify part of the facade, but the requirements vary from room to room. A waiting room, a laboratory, a consultation room and an imaging room do not necessarily call for the same daylight, the same privacy or the same acoustic separation.
The build-up of the envelope is studied according to the climate, the exposure, the thermal needs, the management of water and air, the acoustics and the fire protection. It remains distinct from the load-bearing structure.
Between the levels, the floor must be considered as a whole: frame, slab or substrate, insulation, ceiling, any resilient layers, penetrations and fire-stopping. The performance sought depends on the complete build-up.
The risers, cables, pipes and equipment that cross a separation must not interrupt the acoustic or fire functions foreseen. The treatment of these passages is prepared at the same time as the services.
In a vertical health centre, moving any function crosses several systems: structure, floor, services, circulation, envelope and safety.
Layout
Schematic plans
These documents are there to make the layout and the envelope shown understandable. They are schematic plans: they constitute neither construction drawings, nor structural drawings, nor a building permit.




Possible adaptations and their technical consequences
A consultation room can be enlarged, divided or joined with a neighbouring room. This change acts on the openings, the suspended loads, the acoustics, the services and the portions of wall available for stability.
A laboratory can be replaced by another activity. The ventilation, the fluids, the loads, the surfaces, the waste and the access conditions must then be re-examined.
An imaging machine can be added or replaced. Its weight, its shielding, its cooling, its supply and its installation route must be compared with the existing provisions before the building is modified.
Moving a function from one storey to another may change the floor loads, the vibration, the risers and the vertical flows. A heavy or heavily equipped room cannot be moved on a plan without restudying its support.
The length of the main levels can be increased by adding bays. That extension nevertheless changes the foundations, the floors, the stability, the circulation, the drainage, the facade and the capacity of the technical equipment.
The lateral zones of the top level that carry no brief may possibly be the subject of a new study. Their occupation is not taken for granted: the existence and the capacity of the floor, the loads, the accesses, the envelope, the services and the fire strategy must be verified.
Adding a further storey is not an ordinary adaptation. It increases the accumulated loads, the horizontal forces and the vertical circulation needs. It must be foreseen from the design stage or be the subject of a complete verification of the structure and the foundations.
A design becomes a project only after study
Site and geotechnics, planning, orientation, climate, structure, foundations, loads, wind, seismic action, envelope, performance, services, regulations and contractual scope are defined for the real case. None of these points is guaranteed by the original documents.